Quaternary Ammonium Sanitizer Concentration Test Strips [01000 ppm]

Intended Use:

This method is suitable for on-site rapid test of quaternary ammonium concentration in quaternary ammonium sanitizer. E.g. testing single-chain or double-chain quaternary ammonium such as cetyl trimethyl ammonium bromide, double decyl dimethyl ammonium chloride, tetradecyl dimethyl benzyl ammonium chloride, etc. The test range is 01000ppm (mg/L).

Instructions:

1Loosen the lid of the box, pull out the 2-3cm long test paper and tear it;

2Soak the test paper in the disinfectant for 1 to 2 seconds, and remove the excess liquid;

3Compare the concentration with the control color card in 8 seconds, and discard the test paper after 8 seconds

4Put the test paper box in a self-sealing bag and seal it for storage.

 

 

dsc_9570-_副本  Operation video

 

Quaternary Ammonium Sanitizer Concentration Test Strips [04000 ppm]

Intended Use:

This method is suitable for on-site rapid test of quaternary ammonium concentration in quaternary ammonium sanitizer. E.g. testing single-chain or double-chain quaternary ammonium such as cetyl trimethyl ammonium bromide, double decyl dimethyl ammonium chloride, tetradecyl dimethyl benzyl ammonium chloride, etc. The test range is 04000ppm (mg/L).

Instructions:

1Loosen the lid of the box, pull out the 2-3cm long test paper and tear it;

2Soak the test paper in the disinfectant for 1 to 2 seconds, and remove the excess liquid;

3Compare the concentration with the control color card in 5 seconds, and discard the test paper after 5 seconds

4Put the test paper box in a self-sealing bag and seal it for storage.

 

 

1105  Operation video

微信图片_20240228081006

 

 

微信图片_20240302113437 Operation video

 

Instructions for use of residual chlorine quick test kit

[Scope of application]

1Determination of free residual chlorine in drinking water.

2Determination of residual chlorine in artificial swimming pool water.

3Determination of residual chlorine concentration on the surface of utensils disinfected with chlorine-containing decontamination agent in catering industry.

[Operation method]

1Add water samples to both the narrow and wide pools of the colorimetric dish up to the mark,

2Put a reagent into a narrow pool, cover it, and shake it up and down for about 60 seconds.

3Stand still for about 10 seconds (no more than 60 seconds) to precipitate the undissolved particles,

4Use a hollowed out board to find the same or similar color scale on the narrow pool and the color chart. The reading on this color scale is the content of free residual chlorine in the water sample in ppm (mg/L).

5If the reading exceeds 1.0mg/L, take 1.0ml of water sample into a narrow pool, dilute with pure water to the 10ml mark, and then measure. The reading result is multiplied by 10 to obtain the residual chlorine content in the water in ppm (mg/L).

[Notes] When the chlorine concentration is too high, the test solution is yellow or not colorless. The sample solution should be diluted before measuring, and the reading result should be multiplied by the dilution multiple.

[Product Storage] Reagents should be stored under closed light, at room temperature, or refrigerated,

 

 

微信图片_20240303091821 Operation video

 

Instructions for the use of chlorine dioxide quick test kit

[Scope of Application] Suitable for on-site rapid testing of chlorine dioxide concentration in water after chlorine dioxide disinfection.

[Operation Method]

1Add water samples to both the narrow and wide cells of the cuvette until they reach the mark,

2Drop 3 drops of reagent A into the narrow pool, cover it, flip it up and down, and gently shake it to mix the reagent well,

3Add one particle of reagent B to the narrow pool, cover it, flip it up and down, and gently shake it for about 60 seconds,

4Let it stand still for about 10 seconds (not more than 60 seconds) to allow undissolved particles to settle,

5Use a hollow board to find the same or similar color scale on the narrow pool and color comparison card. The reading on this color scale is the content of chlorine dioxide in the water sample, ppm (mg/L).

[ Attention]

1If the reading exceeds 2.0mg/L, 1.0ml of water sample can be taken into a narrow cell, diluted with pure water to 10ml of the scale line, and then measured. The reading result multiplied by 10 is the chlorine dioxide content in the water, mg/L.

2When the concentration of chlorine dioxide is greater than 10 mg/L, the test solution shows yellow or no color. The sample should be diluted before measurement, and the reading should be multiplied by the dilution factor.

[ Product Storage] Reagents should be stored under closed light, at room temperature, or refrigerated.

 

 

2_副本

Rapid determination of available chlorine

(instructions for chlorine test paper)

 

[scope of application]

this method can be used for the rapid test of effective chlorine content in chlorine containing disinfectants, with the test range of 10 ~ 2000ppm (mg / L).

[Operation steps]

1gently rotate the box cover and draw out the test paper with a length of 2 ~ 3cm,

2 Immerse the test paper in disinfectant for 1-2 seconds, remove and shake off excess liquid;

3Compare and quantify with the color chart within 10 seconds;

4gently rotate the box cover, block the test paper, and put it back into the self sealing bag for storage.

[remarks]

The test paper should be stored in a cool and dry place.

 

 

微信图片_20240313180950 Operation video

 

On site rapid detection of surface cleanliness of catering utensils

Instructions for using the cleanliness detection card

[ Scope of Application]

This method is suitable for on-site rapid detection of the cleanliness and hygiene status of catering utensils, food processing utensils, and operating countertops.

[ Detection Principle]

If dining utensils and food processing utensils are not cleaned thoroughly, there will often be protein residues. Protein is a breeding ground for microorganisms and a component of bacteria. This method utilizes the principle that specific reagents can react with residual proteins on the surface of an object to produce color, in order to determine whether the surface of the object is hygienic and the degree of hygiene.

[ Operation Method]

1Drop 2 drops of wetting agent onto the surface of the tested object.

2Take out a piece of testing card, peel off the surface film of the test paper, face the area where the wetting agent is added, and cross and wipe back and forth in an area of 10 × 10cm. image002

3Place the wiped test card flat with the test paper facing upwards.

4Drop 1 drop of developer onto the test paper, and within 3 minutes, compare the color of the test paper with the reference color card.

5The comparison results are divided into clean, slightly unclean, unclean, and deeply unclean.

[ Precautions]

1Each detection card is disposable.

2Do not touch the testing area of the test strip with your hands.

3If there is liquid on the surface of the object to be inspected, wait until the liquid is slightly dry before conducting the inspection.

4This product is valid for 12 months when stored at room temperature.

5Product configuration: 50 quick test cards, 1 bottle of wetting agent and 1 bottle of color developer, and 1 color control card.

 

 

20240410

Nitrite 0100 ppm test paper

Scope of Application This test strip is suitable for on-site rapid detection of nitrite content in food and water.

Instructions

1) Dip test strip into test solution for 2-3seconds.

2) Remove and shake off excess

 liquid .

3) Wait 60 seconds , then compare test pad with color chart .

Result Calculation

1) Nitrite content in liquid samples: is the number indicated next to the color chart.

2) Nitrite content in solid or semi-solid samples: Multiply the number marked next to the color card by the dilution factor of the sample.

3)Nitrite content in food: calculated as NaNO2.

4) Nitrite content in water: Calculated in N, divide the number marked next to the color chart by 5.

Precautions

1After decolorizing the colored sample, measure it or dilute it with pure water to colorless or light color before testing.

2This method is a rapid on-site detection method, and accurate quantification is based on national standard methods.

3Store in a cool and dry place.

 

 